A1210 settings
Door
With direct doors only
The A1210 controller can control one directly, meaning that the lock, monitor, and REX devices are connected to the physical connections on the controller.
Select the door from the dropdown list (you may need to create it first).
With SimonsVoss SmartIntego
In combination with wireless locks from SimonsVoss SmartIntego, each controller can still manage one door directly. In addition, a controller can manage up to 30 (recommended max value) wireless locks via one or more IP-connected hubs. One SmartIntego hub can manage maximum 16 doors and has a range of 20 - 30 meters.
The connection between the SmartIntego hub and the controller is done on the hub page.
Lock settings
The A1210 controller has one relay that can be configured in the actual hardware (by moving a jumper) to deliver either a potential free contact, 12V, or 24V when activated. It is necessary to specify which door it belongs to by using the dropdown field.
It is also necessary to specify whether it should be configured as fail-safe or fail-secure:
- Fail-secure means that the door is locked if the power fails (it is secure from intruders on the outside). This is the default.
- Fail-safe means that the door is unlocked if the power fails (it is safe for people on the inside, e.g. in the event of a fire).