Doors: Difference between revisions
Jump to navigation
Jump to search
Telcredstaff (talk | contribs) (→Status) |
Telcredstaff (talk | contribs) (→Status) |
||
Line 31: | Line 31: | ||
* Locked. The door is locked with one lock. If the door has two locks, lock 2 is unlocked. |
* Locked. The door is locked with one lock. If the door has two locks, lock 2 is unlocked. |
||
* Double locked. The door has two locks and both are locked. |
* Double locked. The door has two locks and both are locked. |
||
* Unknown. It is not possible to determine the lock |
* Unknown. It is not possible to determine the lock state, e.g. because the controller has not been configured yet. |
||
Possible values for ''Door state'' are: |
Possible values for ''Door state'' are: |
Revision as of 18:25, 11 April 2018
Settings
On the door detail page, the administrator can see and change settings relevant to the individual door. The settings are:
- Name. Should be something meaningful to the administrator (and the end users if they use mobile access through either Telcred Entry or Visits).
- Description. Optional
- Door groups. Optional. For more information on door groups, see this page.
- Access time. This is the time the lock stays unlocked after a credential has been accepted by the reader.
- Open too long alarm. After this time the alert Door left open will be generated and the reader will indicate an alarm.
- Pre-alarm. The number of seconds before Open too long time that the reader will warn the user to close the door.
- Unlock. The door will be unlocked according to a schedule (e.g. weekdays between 09.00 and 17.00). If the door has two locks, both will be unlocked.
- Unlock lock 2 only. Allows to unlock only the second lock according to a schedule (typically a night lock / motor lock).
Status
Three statuses are displayed in the right-hand column for a door:
- Controller status
- Lock state
- Door state
Possible values for Controller status are:
- Online
- Offline
- Incomplete configuration. This means that the controller is not fully configured yet and has never been online.
- Ready to connect. This means that the controller is fully configured and ready to be connected to the Telcred service.
Possible values for Lock state are:
- Unlocked
- Locked. The door is locked with one lock. If the door has two locks, lock 2 is unlocked.
- Double locked. The door has two locks and both are locked.
- Unknown. It is not possible to determine the lock state, e.g. because the controller has not been configured yet.
Possible values for Door state are:
- Open
- Closed
- Unknown
If the door has no door monitor, the door state will always be unknown. It could also be unknown due to the fact that the controller is currently offline.