On the door detail page, the administrator can see and change settings relevant to the individual door:



[[File:Door_detail_page.png|Door detail page]]
[[File:Door_detail_page.png|Door detail page]]


On the door detail page, the administrator can see and change settings relevant to the individual door. The settings are:

* ''Name''. Should be something meaningful to the administrator (and the end users if they use mobile access through either [[Telcred Entry]] or [[Visits]]).
* ''Name''. Should be something meaningful to the administrator (and the end users if they use mobile access through either [[Telcred Entry]] or [[Visits]]).
* ''Description''. Optional
* ''Description''. Optional

Revision as of 15:18, 11 April 2018

Door detail page

On the door detail page, the administrator can see and change settings relevant to the individual door. The settings are:

  • Name. Should be something meaningful to the administrator (and the end users if they use mobile access through either Telcred Entry or Visits).
  • Description. Optional
  • Door groups. Optional. For more information on door groups, see this page.
  • Access time. This is the time the lock stays unlocked after a credential has been accepted by the reader.
  • Open too long alarm. After this time the alert Door left open will be generated and the reader will indicate an alarm.
  • Pre-alarm. The number of seconds before Open too long time that the reader will warn the user to close the door.
  • Unlock. The door will be unlocked according to a schedule (e.g. weekdays between 09.00 and 17.00). If the door has two locks, both will be unlocked.
  • Unlock lock 2 only. Allows to unlock only the second lock according to a schedule (typically a night lock / motor lock).